PMDF System Manager's Guide


Previous Contents Index

31.3 Message Circuit Checking

The PMDF message circuit checking facility may be used to monitor the health of the PMDF system and of other e-mail connected systems, by periodically looping messages through (back to the circuit check facility) and monitoring on the delivery time for the loop to complete.

The PMDF manager configures the facility to periodically send messages to loopback addresses (addresses that will loop through PMDF channels or remote systems and come back to the circuit checking facility). The sizes and other aspects of such messages may be controlled. A circuit check detached process runs, that wakes up periodically and sends out circuit messages and looks for which circuit messages have arrived back. And the facility maintains binned counters for the lengths of time the messages take to complete their circuit. Thus the components are:

These components will be discussed further in the subsections below.


Previous Next Contents Index